Don’t let high ambient temperatures de-rate your production. DUBICOOL engineers Adiabatic Pre-Cooling and Inlet Air Cooling systems that allow your Gas Turbines, Condensers, and Transformers to run at 100% load all summer long.
The Challenge: The “Derating” Curve
Designed for Europe. Installed in the Desert.
Most industrial equipment is rated for an ambient temperature of 35°C (ISO conditions). In the GCC, summer temperatures frequently exceed 48°C. This 13-degree gap causes massive operational losses:
-
📉 Capacity Loss: Gas Turbines and Generators lose ~1% output for every degree rise.
-
🛑 High Pressure Trips: Chillers and refrigeration racks cut out exactly when you need them most.
-
⚙️ Component Fatigue: Overheated oil and windings shorten the lifespan of transformers and motors.
The Solution: Adiabatic & Inlet Cooling
Artificial Climate for Your Machines.
We create a cool micro-climate directly at the air intake of your equipment. By lowering the intake air temperature by 10–15°C, we effectively “trick” the machine into thinking it is operating in a mild winter climate.
Technology A: Adiabatic Pre-Cooling (Retrofit)
-
The Application: Air Cooled Chillers, Dry Coolers, Condensers.
-
The Tech: Mesh-mounted misting grids or “Media Pads” installed in front of the coil.
-
The Benefit: Reduces head pressure, lowers amp draw by 30%, and prevents high-pressure trips.
Technology B: Turbine Inlet Air Cooling (TIAC)
-
The Application: Gas Turbines, Large Generators, Air Compressors.
-
The Tech: High-pressure fog arrays placed in the filter house or intake duct.
-
The Benefit: Increases air density (mass flow), directly boosting power output (MW) by up to 20% during peak heat.
Applications by Equipment
Targeted Retrofits for Critical Assets.
| Equipment | The Issue | The DUBICOOL Solution |
| Air Cooled Condensers (ACC) | High head pressure, fans running at 100%. | Adiabatic Misting: Drops inlet air temp by 12°C. |
| Gas Turbines | Lower MW output, high fuel consumption. | High-Pressure Fog: Increases air density for max power. |
| Power Transformers | Overheating oil, reduced load capacity. | Deluge/Mist Cooling: Active surface cooling for radiators. |
| VRF / HVAC Units | Tripping on high pressure during midday. | Smart Misting Kits: Automated cooling when ambient > 40°C. |
Technical Trust Signals
Safe for Your Equipment.
-
Zero-Wetness Guarantee: Our adiabatic systems are calculated to ensure water evaporates before touching the fins or coils. No corrosion, no scaling.
-
Treated Water Supply: All systems include Reverse Osmosis (RO) or Water Softening units to prevent mineral deposits on your expensive assets.
-
Smart PLC Integration: The cooling system talks to your equipment. It ramps up only when the load increases or ambient temp rises, saving water.
Run at Full Load. All Summer.
Stop accepting “summer derating” as a fact of life. Retrofit your assets with DUBICOOL efficiency systems.
Get a Free consultation